Zurich II Data Center Overview
Nestled within the idyllic Swiss landscape, our ZRH2 data center will be just 30 minutes away from the vibrant heart of Zurich. Situated on three acres (one hectare), ZRH2 will feature a single two-story facility with 24MW of capacity. Thoughtful green initiatives will be built throughout the 226,000-square-foot (21,000 square meters) data center, including air source and water source heating pumps to reutilize waste heat for administrative spaces and neighboring buildings. ZRH2 will offer 300W/SF (3.2kW/M²) average densities to power your next generation applications.
We’re pleased to offer you all the advantages that come with choosing Vantage Data Centers. You’ll find a unique combination of people and technology: cooling and power that’s both sustainable and reliable; flexible room design and rigidly enforced physical security; and amenities that keep your staff happy—all backed by operational excellence at every location as we scrupulously adhere to the same service and delivery standards across the globe.
Data Center Features
Power
Vantage’s ZRH2 data center will feature the most state-of-the-art electrical equipment to ensure maximum efficiency and reliability. The data center will offer N+1 redundancy across all systems, all supported by a world-class in-house operations team ensuring customer uptime.
- Power provided by EKZ
- Multiple, diverse power feeds supporting the data center
- 400V electrical configuration
- All systems 100% concurrently maintainable
Cooling
Vantage’s ZRH2 Zurich data center will use a highly efficient closed-loop chilled water system generated through air-cooled chillers. The cooling system will also include an integrated economizer capability that allows reduced compressor energy based on outside ambient temperature, so when weather is favorable, cooling becomes more sustainable and less resource intensive.
- Computer Room Air Handling (CRAH) units located in two galleries on opposite sides of each data module allow for highly efficient airflow distribution
- Closed-loop chilled water system with air-side economizers
- N+1 overall, N+2 component-level redundancy across mechanical systems
- Water Utilization Efficiency (WUE) will be near zero (liters/kW/hr) using the latest cooling design
Connectivity
ZRH2 will offer multiple, diverse fiber pathways into the data center with access to both dark and lit fiber. The data center will be carrier neutral, giving you the flexibility to manage your own network.
- Major fiber-based service providers operating within a few miles of the data center
- Two Meet-Me-Rooms (MMRs) allowing for diverse paths and multiple connectivity options
- Two points-of-entry (POEs) ensuring maximum path diversity for inbound carriers
- Diverse fiber pathways into the data center (minimum two paths per carrier)
Security
Stringent security and safety measures are hallmarks of every Vantage data center. Our Zurich II data center will be no exception, so you can rest easy when it comes to the security of your digital assets.
- On-site security operations center with patrols 24x7x365
- Perimeter security gates and fencing
- CCTV on all access control points throughout the entire data center
- Dual authentication (access badge/PIN and biometric readers) for customer and critical infrastructure areas
- Visitor management system and badging to control and track onsite personnel all the time
Amenities
A space where your employees can work efficiently, as well as relax and recharge, is essential. To provide that superior customer environment, our Zurich II data center will offer dedicated office space, conference rooms and large-scale break room facilities with food, games, entertainment and more.
- Customizable offices and workspaces dedicated to individual customers
- Secure storage with easy access between data modules
- Multiple conference rooms and meeting spaces
- Conveniently located approximately 30 minutes away from the Zurich City Center and 15 minutes away from Zurich Kloten International Airport
Sustainability
Vantage Data Centers builds and operates our data centers in ways that prioritize sustainability and environmental responsibility, all while delivering the reliability that is our hallmark. Our baseline approach includes using renewable energy whenever possible, limiting carbon footprints and maintaining energy efficient operations with industry-leading PUEs. Our ZRH2 Zurich data center delivers on this promise.
- Hyper-efficient cooling with outside air economization using minimal water
- Air and water source heat pumps to recover waste heat to use for warming administrative spaces
- District heating network connection to export waste heat for use by neighboring buildings within the local community
- Rainwater infiltration
- Highly durable wooden facade to align with the look and feel of the neighborhood
- Small things that add up over time: recycling, motion-sensor LED lights, drought-resistant landscaping and more
Related Resources
Zurich (ZRH2) Data Center Overview
A Guided Data Center Tour
Zurich Data Center Market Heats Up as FLAP Gets Tapped