Frankfurt Data Center Campus

Europe’s Prime Data Center Location

FRANKFURT CAMPUS OVERVIEW

In the most sought-after data center market in Europe, Vantage’s first Frankfurt data center campus will be in Offenbach, just one kilometer from the main data centers and peering points in Frankfurt and a 15-minute drive from the airport. It will sit on approximately 8 acres (3 hectares) and, once fully developed, the 650,000 sq. ft. (60,000 sq. m.) campus will be comprised of four multi-story, state-of-the-art data centers offering a combined 55MW of critical IT load. The first building, scheduled for delivery in late 2020, will include 15MW of IT capacity.

This campus is a partnership between Vantage Data Centers, utility provider Energieversorgung Offenbach and general contractor DC-DataCenter-Group

  • Located on an 8-acre (3 hectares) campus
  • 55MW of critical IT load
  • Four planned, multi-story data centers
  • 650,000 sq. ft. (60,000 sq. m.) of leasable data center space
  • 200W/sq. ft. (2.15kW/sq. m.) average density
  • Class A building amenities including office, conference rooms, break rooms and more

GET THE DATA SHEET GET MORE INFO

Our commitment to offering a superior customer environment is unsurpassed. Providing an atmosphere within each data center that helps you and your personnel relax, recharge and work more efficiently is essential. This Frankfurt campus will include dedicated customer office space, always-available conference rooms and large-scale break room facilities.

  • Dedicated offices and workspaces customizable to your needs
  • Multiple conference rooms and meeting spaces throughout the campus
  • Secure storage with easy access between data modules
  • EV charging stations for cars and bikes
  • Easy access to Frankfurt Airport:15-minute drive, 30 minutes by train
GET CAMPUS UPDATES

Vantage’s new Frankfurt campus will provide N+1 redundancy across all systems. An on-campus substation and state-of-the-art electrical equipment are the foundation of maximum efficiency and reliability, ultimately ensuring customer uptime and reliability thanks to the support from a world-class in-house operations team.

  • Designed to feature a low 1.3 PUE
  • Power provided by EVO (the local utility provider) from an on-campus substation
  • Multiple, diverse power feeds supporting the campus
  • All systems 100% concurrently maintainable
GET CAMPUS UPDATES

Except for the first building using air-to-air units into an N+1 topology, Vantage’s Frankfurt campus will use a highly efficient closed-loop chilled water system generated through air-cooled chillers. An integrated economizer capability will allow reduced compressor energy based on outside ambient temperature–when weather is favorable, cooling becomes more sustainable and less resource intensive.

  • N+1 overall, N+2 component-level redundancy across mechanical systems
  • Computer Room Air Handling (CRAH) units located in two galleries on opposite sides of each data module allow for highly efficient airflow distribution
  • Closed-loop chilled water system with air-side economizers
  • Water Utilization Efficiency (WUE) is near zero (liters/kW/hr) using the latest cooling design
GET CAMPUS UPDATES

Fiber pathways into the Vantage Frankfurt campus are multiple and diverse, with access to both dark and lit fiber. Also, the campus is carrier neutral, giving customers the flexibility to manage their own network.

  • Two meet-me-rooms (MMRs) for each data center on campus, allowing for diverse paths and multiple connectivity options
  • Three points-of-entry (POEs) for the campus, ensuring maximum path diversity for inbound carriers
  • More than 20 carriers already connecting in Offenbach
GET CAMPUS UPDATES

Stringent security and safety measures are hallmarks of every Vantage campus. Our Frankfurt data center campus is no exception, so you can rest easy when it comes to the security of your data.

  • On-site security operations center with patrols 24x7x365
  • Fencing around the perimeter
  • CCTV on all access control points throughout the entire campus
  • Dual authentication for customer and critical infrastructure areas
  • Visitor Management System with controlled and monitored access points and stringent access control policy